SGCMS
Last updated
Last updated
Simplified Generalized Conforming Mixed Shell Element
A planar shell element uses SGCMQ for membrane action and DKT4 element for plate action.
Number of Nodes: 4
Number of DoFs: 6 (Translation, Translation, Translation, Rotation, Rotation, Rotation)
Integration Membrane: Five-Point Irons Scheme
Integration Plate: 3rd Gauss Scheme
If the nonlinear geometry switched on, the transformation between the global and local reference frames will depend on the current displacement. The nonlinear transformation is similar to the corotational transformation, and the local response is still linear. Thus, it follows "large displacement, small deformation" assumption.